The subscriber calls to say the internet is down, and when the agent asks them to look at the device, they mention a red light labeled LOS. Knowing what LOS on an ONU means is the first step toward an expensive decision: whether to send a technician, and where to send them.
In practice, LOS is almost always a physical problem that can't be fixed over the phone. Once support knows whether light is missing entirely or the signal is only weak, and whether the problem affects one subscriber or a whole street, that changes who goes out in the field and what they carry in the truck.
What does LOS mean on an ONU?
LOS, short for Loss of Signal, is the alarm an ONU raises when it receives no optical signal from the OLT, or receives so little that the receiver can't work with it. G-PON maintenance alarms belong to the transmission convergence layer described in ITU-T G.984.3, and each vendor maps that onto its LEDs in its own way.
On most models, a solid red LOS means no light is arriving at all, and a blinking LOS usually shows up when some light arrives but below what the receiver can use. Because this behavior varies a lot from one model to another, give your tier 1 agents the manuals for the equipment actually deployed in your fleet.
On the PON LED, blinking generally means the ONU is trying to register with the OLT, and solid means it is registered. If the subscriber describes PON solid and LOS off, the fiber is delivering and the problem sits further along, in authentication, the router or the Wi-Fi, which is the path we cover in slow internet complaints.
LOS or weak signal: what's the difference in practice?
LOS is the absence of usable light, while a weak signal is light that arrives with little margin, enough for the ONU to connect and browse, though the connection drops whenever the power fluctuates a bit. Received power, or RX, is measured in dBm on a logarithmic scale where more negative values mean less light, and every connector, splice and splitter stage eats into the link's optical budget.
Power levels for each optical module class are defined in ITU-T G.984.2, but the real margin depends on the losses along each route in your plant. Each ISP should set its own minimum and maximum, based on the classes it uses and what it measured during installations, and treat anything outside that range as an alarm. A signal that's too strong causes trouble too, because it saturates the receiver and leads to packet loss, which happens with subscribers very close to the OLT and little splitting along the way.
Main causes of LOS inside the home and in the network
LOS causes fall into two groups: what's inside the home, which the subscriber can check with some guidance, and what's in the outside plant, which only the field team can fix.
Inside the home you'll find a loose patch cord at the ONU or at the optical wall outlet, fiber bent behind a piece of furniture moved during cleaning, a cable pinched in a door or window, and a drop cable chewed by the dog. A dirty connector also kills the signal, but cleaning is the technician's job. When guiding the subscriber, warn them not to look directly into the end of the fiber or the connector.
Outside the home, the list includes a drop cable torn at the pole by a tall truck, tree trimming or sidewalk work, a faulty connector or splice in the distribution box, a damaged splitter, and a break in a distribution or trunk cable, which takes down everyone downstream of the cut at once.
One subscriber or a whole neighborhood?
When several subscribers in the same area lose signal at the same time, the cause is in the network (distribution box, splitter or cable), and when it's only one, it's in the drop, the home or the ONU. On the OLT, this shows up as several ONUs on the same PON port going into LOS within the same minute. The catch is that not every tier 1 agent has access to the OLT, and a neighborhood outage reaches support in pieces, one call at a time.
IXC ACS helps reveal this pattern from the CPE side. An ONU in LOS can't send an inform, so the ACS marks it as Offline once the periodic interval plus a margin of about 20% has passed (with the default 20-minute interval, roughly 24 minutes), and the Last connection field records when it last checked in. Offline on its own doesn't prove the subscriber has no internet, but combined with the LOS they describe on the phone, it completes the picture. The IXC ACS documentation on offline status recommends comparing the case with the rest of the fleet: one device offline points to electricity, optical power or the session, and many at once point to the network.
If the subscribers who called in the last half hour are in the same area and went offline together, tier 1 already knows there's no point asking anyone to touch the cable and escalates to the network team. The ACS doesn't read the OLT or know the topology of your distribution boxes, so cross-checking against the plant is still the job of whoever knows the network.
How do you diagnose optical power without a truck roll?
To diagnose optical power remotely, you read the TX and RX values the ONU itself reports to the ACS, which works as long as it still connects, even poorly. With total LOS no new reading comes in, but the last one before the drop is already useful. An RX that was sitting at the limit and then vanished suggests degradation, like a dirty connector or stressed fiber, while a healthy RX that collapsed all at once suggests a cut or a pulled connector.
A short script for tier 1:
- Ask about the state of the LOS and PON LEDs and whether anything changed in the home.
- Check the device status and Last connection, and see whether other subscribers in the area dropped within the same window. If they did, open a network incident.
- If the ONU is online, read the RX. The IXC ACS AI assistant answers the question is this customer's optical power within range? with a verdict based on the TX/RX alarms the ISP configured under System > Settings, Network tab, so the agent doesn't have to interpret the number.
- If the case is isolated and the ONU is offline, have the subscriber check the patch cord and the wall outlet, without looking into the fiber end.
- If a visit is needed, record in the work order the last RX reading, the time of the drop, whether the case is isolated or widespread, and what the subscriber already checked, so the technician knows whether to bring a cleaning kit, connectors or splicing material.
For the NOC, the Optical Power view lists devices with TX or RX outside the standard the ISP defined. It shows what the ONUs reported, with no prediction involved, and helps schedule a check on the ones at the limit before the subscriber calls about drops.
Across tens of thousands of support interactions at a Brazilian ISP, over 6 months between 2025 and 2026, subscribers with CPEs in IXC ACS had 62% fewer truck rolls than those without CPEs in the ACS, according to the ROI calculator. A broken fiber still needs someone up the pole. Remote diagnosis makes sure that visit leaves with the right material, and it holds back the ones that never needed to happen.
Frequently asked questions
Can a red LOS be the ISP's problem rather than the subscriber's home? Yes. A cable break or a fault in a distribution box or splitter lights LOS on every ONU downstream of the failure point, so the first step is checking whether other subscribers in the area dropped at the same time.
Does rebooting the ONU fix LOS? Almost never, because a reboot doesn't make light arrive. It only makes sense after ruling out the physical side, and even then the subscriber tends to call back if the cause is a connector or the fiber.
Can the subscriber clean the fiber connector? It's not recommended. Without the right material they can damage the connector, and looking straight into the fiber end is risky for the eyes. They can check that the cord is seated and free of bends, and leave the cleaning to the technician.
What to adjust in your operation this week
Start with the optical power alarms, because without your plant's range configured, any verdict, yours or the tool's, stays generic. Then add the script above to the tier 1 playbook and agree with the field team on a simple dispatch rule that separates what goes to the network team, what needs a splice and what is just connector cleaning. When the ONU gets replaced, automatic provisioning can save a second visit just to configure it. If you'd like to see how this works in your fleet, click the button below and talk to our team.